Air treatment


Products > Air Treatment

Air quality can have a significant impact on compressed air systems. Properly treated compressed air will improve productivity, system efficiency and product or process quality.
Choosing the appropriate dryers and filters is very important.
Ingersoll Rand has the widest selection of air treatment products and application knowledge to protect your investment and compressed air system.

Non-Cycling Refrigerated Dryers
Ingersoll Rand non-cycling refrigerated dryers will deliver a consistent pressure dew point of 38F to 50F (3C to 10C). The dryers are available in wide range of sizes with a variety of options. The non-cycling design provides reliable and economical operation while delivering moisture free air.

Model D_IN-A

Capacity Range: 7-212 cfm (0.2-8 m3/min)
Pressure Dew Point: 38F to 50F

(3C to 10C)
ISO Class 4 to 6
Cooling Method: Air-cooled
Voltage: 115/1/60, 230/1/50
Maximum Pressure: 203 psig (14 barg)
Maximum Ambient (air cooled): 122F

(50C)
Maximum Inlet Temperature:140F (60C)
Refrigerant: R-134A

Model D_IN-A

Capacity Range: 10-90 m3/min

(353-3178 cfm)
Pressure Dew Point: 3C (38F)
ISO Class 4
Cooling Method: Air-cooled
Voltage: 230/1/50, 400/3/50
Maximum Pressure: 12 barg (174 psig)
Maximum Ambient (air cooled): 46-50C

(115-122F)
Maximum Inlet Temperature: 60C (140F)
Refrigerant: R-507

Model D_IN-A/W

Capacity Range: 102-380 m3/min

(3600-13420 cfm)
Pressure Dew Point: 3C (38F)
ISO Class 4
Cooling Method: Air-cooled and

water-cooled
Voltage: 400/3/50
Maximum Pressure: 12-14 barg

(174-203 psig)
Maximum Ambient (air cooled): 46C

(115F)
Maximum Inlet Temperature: 65C (156F)
Refrigerant: R-407C

   

Model D_IT-A

Capacity Range: 15-100 cfm

(0.42-3 m3/min)
Pressure Dew Point: 38F to 50F

(3C to 10C)
ISO Class 4 to 6
Cooling Method: Air-cooled
Voltage: 115/1/60, 230/1/50
Maximum Pressure: 203 psig (14 barg)
Maximum Ambient (air cooled): 122F

(50C)
Maximum Inlet Temperature: 200F (90C) 
Refrigerant: R-134A

   

Cycling Energy Efficient Refrigerated Dryers
Ingersoll Randís unique line of Cycling Refrigerated Dryers offer the ultimate in energy savings. The dryers are constructed with quality components to ensure superior performance and reliability.

Model TMS

Capacity Range: 0.36-88 m3/min

(13-3108 cfm)
Pressure Dew Point: 2C(36F)
ISO Class 4
Cooling Method: Air-cooled
Voltage: 230/1/50, 400/3/50
Maximum Pressure: 16 barg (230 psig)
Maximum Ambient (air cooled): 47C

(117F)
Maximum Inlet Temperature: 55C (131F)
Refrigerant: R-134A & R-404A

Capacity Range: 510-6460 cfm

(14.4-183 m3/min)

Pressure Dew Point: 38F (3C)
ISO Class 4
Cooling Method: Water-cooled
Voltage: 460/3/60
Maximum Pressure: 680 psig (47 barg)
Maximum Ambient (air cooled): 120F (49C)
Maximum Inlet Temperature: 120F (49C)
Refrigerant: R-404A

  

 

High-Efficiency Cycling Dryers model D_ec

Capacity Range: 0.7-108 m3/min

Pressure Dew Point: 2C(36F) ISO Class 4 
Cooling Method: Air-cooled
Voltage: 230/1/50, 400 /3/50
Maximum Pressure: 13-14 barg

Maximum Ambient (air cooled): 45-50C
Maximum Inlet Temperature: 60C

Refrigerant: R-134A & R-407C

     

Heatless Desiccant Dryers
Ingersoll Randís heatless desiccant dryers deliver superior compressed air quality at a constant -40F to -100F (-40C to -70C) pressure dew point. Our heatless dryers are simple to operate, dependable and very economical.

Heatless D_IL

Capacity Range: 120-1800 cfm

(3.4-51.0 m3/min)
Pressure Dew Point: -40F to -100F

(-40C to -70C)
ISO Class 1 to 2
Voltage: 115V/1PH/60HZ (230V/1PH/50HZ)
Maximum Inlet Pressure: 150 psig

(10.3 barg)
Maximum Inlet Temperature: 120F (50C)
Desiccant Type: Activated alumina

Modular Heatless D_IM

Capacity Range: 3-176 cfm

(0.08-5.0 m3/min)
Pressure Dew Point: -40F to -100F

(-40C to -70C)
ISO Class 1 to 2
Voltage: 115V/1PH/60HZ (230V/1PH/50HZ)
Maximum Inlet Pressure: 189 psig (13 barg)   
Maximum Inlet Temperature: 122F (50C)
Desiccant Type: Activated alumina

   

Heated Desiccant Dryers
Ingersoll Randís heated desiccant dryers incorporate an external heat source to enhance drying efficiency and lower operating cost.

Externally Heated EH

Capacity Range: 400-2100 cfm

(11.3-59.5 m3/min)
Pressure Dew Point: -40F to -100F

(-40C to -70C)
ISO Class 1 to 2
Voltage: 460V/3PH/60HZ (400V/3PH/50HZ)
Maximum Inlet Pressure: 150 psig

(10.3 barg)
Maximum Inlet Temperature: 122F (50C)
Desiccant Type: Activated alumina

Heated Blower D_IB

Capacity Range: 1000-8000 cfm

(28.3-226.5 m3/min)
Pressure Dew Point: -40F to -100F

(-40C to -70C)
ISO Class 1 to 2
Voltage: 460V/3PH/60HZ (400V/3PH/50HZ)
Maximum Inlet Pressure: 150 psig (10.3 barg)
Maximum Inlet Temperature: 122F (50C)
Desiccant Type: Activated alumina

  

Heat of Compression Desiccant Dryers
Ingersoll Randís Heat of Compression (HOC) desiccant dryers are the most energy-efficient dryers available. The dryers recover the heat that is a natural by-product of the compression process. This ďfreeĒ heat is utilized in the air drying process to provide moisture-free air, while consuming virtually no energy.

H-Series

Capacity Range: 741-15000 cfm
(20 - 402 m3/min)
Pressure Dew Point: 0F to -60F
(-18C to -51C)
ISO Class 2 to 3
Cooling Method: Water-cooled
Voltage: 115V/1PH/60HZ
(230V/1PH/50HZ)
Cycle Time: 60 minutes
Maximum Inlet Temperature: 400F
(204C)
Desiccant Type: Activated alumina

HC-Series

Capacity Range: 677-14743 cfm
(18-395 m3/min)
Pressure Dew Point: -40F (-40C)
ISO Class 2
Cooling Method: Water-cooled
Voltage: 460V/3PH/60HZ (400V/3PH/50HZ)     
Cycle Time: 8 hours
Maximum Inlet Temperature: 400F (204C)
Desiccant Type: Activated alumina

 

Filters
With a wide variety of product offerings, Ingersoll Randís air filters provide superior air quality to almost every compressed air application in the industry. Ingersoll Rand is a world class producer of air filtration products. With a wide variety of product offerings, Ingersoll Randís air filters provide superior air quality to almost every compressed air application in the industry.

Standard Cast & Fabricated

Capacity Range: 21-17000 cfm
(0.6-468 m3/min)
Filtration Grades: General purpose, high
efficiency, dust particle, activated carbon
ISO Class 1 & 2
Maximum Operating Pressure: 232 psig
(16 barg)   
Maximum Operating Temperature: 150F
(66C),  86F (30C) for activated carbon

 

Energy Efficient Filters

Capacity Range: 125-10000 cfm
(3.5-283.2 m3/min)
Filtration Grades: High efficiency
Pressure Drop: 0.5 psig (0.03 barg)
Maximum Operating Pressure: 150 psig
(10.3 barg)
Maximum Operating Temperature: 125F
(52C)   
Minimum Operating Temperature: 34F (1C)   
Element Life: 10 years

   

Air and Water Cooled Aftercoolers
Compressed air contains very high levels of liquid condensate, the effective removal of which leads to reduced maintenance costs, enhanced system operation and improved product quality. Aftercoolers represent the vital first step in this process, eliminating up to 80% of the condensate present within compressed air.

Air Cooled ABC

Capacity Range: 0.6-75 m3/min

Minimum Operating Pressure: 0.5 barg
Maximum Operating Temperature: 150C 

Water Cooled WBC

Capacity Range: 1.2-550 m3/min

Minimum Operating Pressure: 0.5 barg
Maximum Operating Temperature: 200C

Minimum Water Temperature: 1C